Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
67
Filter properties
In the "Filter properties" area, you can adapt the properties of the individual filters. To allow
filter functions to take effect, the information defined in the filter must be read out from the
transponders and compared with the filter criteria.
Table 7- 12 Description of the filter properties
Property
Description
Name
Input box for assigning a logical name/ descriptive title to the filter.
Bank Drop-down list for selecting the memory bank in which the memory area
is located.
Start address
Address starting at which the filter will be checked.
Value range 0 ... 65535 bytes
Length Number of bytes to be checked starting at the start address. The value
specified here affects the length of the input boxes "Mask" and "Value".
Value range
1 ... 1024 bytes
Criterion Specifies which value the checked positions must contain HEX repre-
sentation).
Possible characters
0 ... 9, A ... F
ASCII Hiding/unhiding the ASCII view.
When the ASCII view is active, the values of the criterion are shown
additionally in ASCII notation. You can edit the values both in the HEX
format or in the ASCII format.
You can choose between the two input modes "Overwrite" and "Insert".
Mask Showing/hiding the mask.
Specifies which positions of the criterion should be checked.
Example: 00FF → Bits 0 ... 8 of the criterion will be checked.
Possible characters
0 ... 9, A ... F
Initialize data Show/hide the view for initializing the data.
Using the initialization function, you can preset the boxes of the criterion
and the mask.
Advanced filter properties
Inclusive/exclusive filters Radio button to specify the condition when the transponder processing
will continue.
Inclusive filter:
The transponder is processed further when the filter criteria mask
and value match.
Exclusive filter:
The transponder is processed when the filter criteria mask and value
do not match.
Unreadable filter data Radio button to specify what happens if the filter data is not legible, for
example because the transponder was not located long enough in the
antenna field. Depending on this setting, such transponders are dis-
carded or processed further.