Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
77
Figure 7-15 The "Settings - Communication" menu item, "OPC UA" tab
In the "OPC UA" area you can make the basic settings for the OPC UA interface. Select the
"Enable" check box to enable the OPC UA interface.
Table 7- 19 Description of the parameters
Application name Name of the OPC UA application of the server. The application name is re-
quired to identify the OPC UA namespace of the reader and should be unique
for each reader within the project.
The application name is part of the URL of the OPC UA server of the reader.
Default port Here you can change the port number of the application. As default, port num-
ber 4840 is used, the standard TCP port for the OPC UA binary protocol.
Minimum
sampling interval
Minimum sampling interval at which the reader samples the process data. The
sampling interval is limited to a minimum value of 10 milliseconds,, to reserve
adequate time for other processes.
Range of values: 10 .. 50 ms