Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF600
94 Configuration Manual, 11/2018, C79000-G8976-C386-07
Figure 7-21 The "Edit transponder" menu item
In this area, you can select the read point with which transponders will be processed.
Select the "EPC-ID in ASCII format" check box to display the EPC-IDs of the transponders in
ASCII code.
The "Identified transponders" area contains a list of the transponders identified by the read
point. To obtain or update list entries, click the "Scan" button. To edit a transponder, select
the required EPC-ID in the list. The selected EPC-ID is highlighted in color. The selected
EPC-ID is also displayed in the "Selected EPC-ID" box.
Select the "Auto scan (5 sec)" check box to update the list entries automatically every 5
seconds.
The EPC-ID selected in the list is displayed in the "Selected EPC-ID" box. In the "Password"
input box, you can enter the access or kill password. You require these passwords to "Lock"
or "Kill" the transponder. You specify the passwords in the section "The "Settings - Tag
fields" menu item (Page 63)".