EasyManua.ls Logo

Siemens Simatic S7-1500 / ET 200MP - Page 232

Siemens Simatic S7-1500 / ET 200MP
385 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protection
10.6 Know-how protection
Automation system
System Manual, 01/2023, A5E03461182-AK
231
Further actions
Further actions that can be carried out with a know-how protected block:
Copying and deleting
Calling within a program
Online/offline comparison
Load
Global data blocks and array data blocks
You protect global data blocks (global DBs) from unauthorized access with know-how
protection. If you do not have the valid password, you can read the global data block but not
change it.
Know-how protection is not available for array data blocks (array DBs).
Setting up block know-how protection
To set up block know-how protection, follow these steps:
1. Open the properties of the respective block.
2. Select the "Protection" option under "General".
Figure 10-2 Setting up block know-how protection (1)
3. Click the "Protection" button to display the "Define protection" dialog.
Figure 10-3 Setting up block know-how protection (2)
4. Enter the new password in the "New password" field. Enter the same password in the
"Confirm password" field.