Software section
3.2 Creating the program
S7-1500
76 Getting Started, 05/2014, A5E03981761-AC
3.2.13.2
Loading blocks for local error handling
Introduction
To illustrate the local error handling, load the blocks of the "ProgLib_LEH" library in the
project. The blocks are used only to demonstrate the local error handling and are otherwise
not used in the project.
Procedure
1. Open the global library, "ProgLib_LEH".
2. Copy the blocks from the master copies into the project.
3. Call the "LAD_Local_Error_Handling" function block in an empty network of the "Main"
block.