Data Exchange with the Central Controller
IP244
C79000–B8576–C860–02
4–52
Byte 29 Main control byte 3
Coolant temperature from
compensationĆPt 100 temperature
Coolant temperature can be set
Value of the
control bits 2
n
Logical
state
Required function
2
0
1
0
1
0
1
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
Must be set by the PLC as a trigger bit at the
end of a machine cycle (only for cascaded
control). The IP 244 resets bit 2
0
.
Free
Bit 7 6 ON times of switching devices
(only if heating current monitoring)
0 0 maximum 100 ms
0 1 maximum 100 ms
1 0 maximum 150 ms
1 1 maximum 200 ms
0
0
1
0
Bit 1: You can inform the IP 244 whether you want it to read 30 or 60 values each via channel 13
(only when special function is selected).
TĆno. 15, byte 6 (duration of acquisition) presets the total time of the readĆin procedure. The
following applies for bit 2
1
= 1 in the main control byte 3: the minimum duration of
acquisition is 3 seconds, otherwise (bit 2
1
= 0) 6 seconds.
Bit 4: Valid for all controllers with cooling outputs: the controller parameters are adapted internally
to the temperature of the coolant (e.g. air, oil water). If bit 4=1 the IP takes message 15 byte
17 as the coolant temperature, otherwise the temperature measured by the
compensationĆPt 100 or operation without thermocouples 0 °C (32 °F) is selected.
Bit 5: Continuous processes are those involving, for example, sheet extrusion or blow molding
machines.
Batch processes, for example, include injection molding machines.
The IP only evaluates this bit if main control byte 1, bit 2 = 1, or with selfĆtuning controllers.
In these cases 3Ćstep controllers operate with temporary IP internal controller parameter
modifications matched to the different machine types described above. In this way, 3Ćstep
controllers react ideally to the different temperature disturbances occurring with the different
machine types. The IP has therefore an optimized disturbance response.
If bits 4 to 7 are transferred to the IP with FB 162, the commands KS, PA or AE
(message 15) must be used.
1
0
Continuous process
batch process
1
0
30 curve values acquired via channel 13
60 curve values acquired via channel 13
Free