INSTALLATION
3-15
Hardware
and Installation User Manual
3.4.5 Setting
Communication Port Baud Rate —TI535 Models
Figure 3-12
shows the baud rate switch assignments for the communication
ports.
Switches 2–4 on the second dipswitch assembly (DIP
2) set
the baud rate
for the RS-422 9-pin port (Port 2). Switches 5–7 set the baud rate for the
RS-232-C/423
25-pin port (Port 1). Switch position does not matter if a device is
not
to be connected to the port.
DIP
2
L
= Left
R = Right
RS–422
Baud rate
23Baud
1200
2400
9600
19200
LR
RL
LL
**
Switch position
4
R
R
R
L
300 R R R
RS–232–C/423
Baud rate
L
= Left
R = Right
56Baud
1200
2400
9600
19200
LR
RL
LL
**
Switch position
7
R
R
R
L
300 R R R
PUSH
LEFT
PUSH
RIGHT
*
Position does not matter
*
Position does not matter
Figure 3-12 Switch Settings — TI535 RS-232-C/RS-423 and
RS-422 Ports
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.comArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com