Communication according to PROFIdrive
3.2 Cyclic communication
Communication
46 Function Manual, 12/2018, 6SL3097-5BD00-0BP0
Overview of closed-loop control
Position actual value sensing in the device is alternatively realized using an:
Indirect measuring system (motor encoder)
Additional direct measuring system
The encoder interface must be configured in the process data.
The control loop is closed via PROFIBUS.
The position controller is located in the controller.
The current and speed control and actual value sensing (encoder interface) are located in
the device.
The position controller cycle is transferred via the fieldbus to the devices.
The slaves synchronize their speed and/or current controller sampling time with the
position controller clock cycle of the controller.
The speed setpoint is specified by the controller.
Figure 3-5 Overview of "Motion Control with PROFIBUS" (example: controller and 3 devices)
Structure of the data cycle
The data cycle comprises the following elements:
Global control telegram (PROFIBUS only)
Cyclic part - setpoints and actual values