06.03
5.7 Handheld terminal HT 6
5-165
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
The HT 6 is parameterized as a machine control panel (MCP) in organization
block OB 100 in the call parameters of function block FB 1.
The HT 6 can be operated either as an MCP substitute or, in addition to an
MCP, as a 2nd operator component.
In order to synchronize several operator components, the PLC program must be
adapted accordingly. This is the user’s (machine manufacturer’s) responsibility.
MCPNum: INT:= 1; // 1: 1 operator component MCP/HT 6 (default)
// 2: Two operator components MCP/HT 6
MCP1In: POINTER; // address of the MCP/HT 6 1 input signals
MCP1Out: POINTER; // address of the MCP/HT 6 1 output signals
MCP1StatSend: POINTER; // Addr. of the send status data MCP/HT 6 1
MCP1StatRec: POINTER; // Addr. of the MCP1 receive status data MCP/
// HT 6 1
MCP1BusAdr: INT:= 14; // default MPI address of the HT 6
MCP1Timeout: S5TIME:= S5T#700MS; // should be kept
MCP1Cycl: S5TIME:= S5T#200MS; // should be kept
MCPMPI: BOOL:= FALSE; // MCP/HT 6 is operated at the “extended”
// MPI bus
The MCP2... parameters are only needed if in addition to the 1st MCP/HT 6 a
HT 6 is additionally used:
MCP2In: POINTER; // address of the MCP/HT 6 2 input signals
MCP2Out: POINTER; // address of the MCP/HT 6 2 output signals
MCP2StatSend: POINTER; // Addr. of the send status data MCP/HT 6 2
MCP2StatRec: POINTER; // Addr. of the MCP1 receive status data MCP/
// HT 6 2
MCP2BusAdr: INT; // MPI address
MCP2Timeout: S5TIME:= S5T#700MS; // should be kept
MCP2Cycl: S5TIME:= S5T#200MS; // should be kept
The parameters listed below serve to synchronize two operator components:
MCP1Stop: BOOL:= FALSE; // 0: Start transfer of the MCP/HT 6 signals
MCP2Stop: BOOL:= FALSE; // 1: Start transfer of the MCP/HT 6 signals
MCP1NotSend: BOOL:= FALSE; // 0: Send and receive mode is active
MCP2NotSend: BOOL:= FALSE; // 1: Only reception of the MCP/HT 6 signals
Notice
A maximum of two MCP/HT 6 can be operated on an MPI line. To be able to
use MCP and HT 6 on an automation system alternately or simultaneously, the
user (machine manufacturer) has to adapt the PLC program accordingly.
For a detailed description of the basic PLC program or of function block FB1,
please refer to:
/FB1/ Description of Functions, Basic Machine: P3, Basic PLC Program
Section: FB 1: RUN_UP Basic program, start-up section
Setting the
communication
parameters (FB 1)
References
5 MPI Communication