06.03
2.12 I/O Module PP72/48
2-104
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
2.12.6 Technical data
Technical data of the I/O modules PP72/48
Safety
Degree of protection IP 00
Class of protection Class of protection I, acc. to VDE 0106 P1:
1982 (IEC 536);
Protection against ingress of solid foreign bodies and
water to IEC 529
Certifications CE/CSA, CE
Power consumption
At nominal load 11W
Mechanical data
Dimensions WxHxD [mm] 194x325x35
Weight approx. 0.3kg
without mounting plate
approx. 1.2kg
with mounting plate
Climatic environmental conditions
Heat dissipation Open-circuit cooling
Operation Storage/transportation
Temperature limit values
0 ... 50°C –20 ... 55°C/–40 ... 70°C
Limit values of rel. humidity
5 ... 95%
not condensing
5 ... 95%
not condensing
Condensation not admissible
Atmospheric pressure 700 ... 1060 hPa 700 ... 1060 hPa
Transportation height – –1000 ... 3000m
Shock loading during transportation
Free fall in transport package
v1000mm
2 Hardware Descri