9.1.4 Setting PROFIBUS address (SIMODRIVE POSMO SI/CD/CA)
For SimoCom U to be able to enter online operation with the SIMODRIVE drives
connected to the PROFIBUS, the PROFIBUS address specified in the S7 proj-
ect (see Section 7.3, page 7-211f) must be set on DP slave POSMO SI/CD/CA
in question using the DIL switches of the PROFIBUS unit in question.
Terminating resistor
inactive = OFF
PROFIBUS address
12345678
2
0
(1)
2
1
(2)
2
2
(4)
2
3
(8)
2
4
(16)
2
5
(32)
2
6
(64)
(reserved)
ON
1234
ON
Terminating resistor active
Example: PROFIBUS address = 37
ON
1234
12345678
ON
OFF=0
ON=1
Switch position
Note:
S The valid settable address are: 3 to 126
S The set address is read by POSMO SI/CD/CA and displayed using
P0918 (PROFIBUS node address).
1234 12345678
1 + 4 + 32 = 37
Fig. 9-2 Setting the PROFIBUS address and terminating resistor
Notice
To set the PROFIBUS address and terminating resistor it is necessary to re-
move the PROFIBUS unit.
For detailed information on start-up of SIMODRIVE POSMO CD/CA and SI uni-
versal drives, refer to:
/POS3/ SIMODRIVE POSMO SI/CD/CA User Manual
Section: Connecting the PROFIBUS unit.