11.1.4 Syntax for alarm text files
The following alarm numbers are available for alarms relating to cycles, compile
cycles and the PLC:
Table 11-2 Alarm numbers for cycle, compile cycle and PLC alarms
Number range Designation Effect Delete
60000–60999 Cycle alarms
Display, NC start disable Reset
61000–61999
(Siemens)
Display, NC start disable,
axis/spindle standstill
Reset
62000–62999 Display Cancel
63000–64999 Reserved
65000–65999 Cycle alarms
Display, NC start disable Reset
66000–66999
(user)
Display, NC start disable,
axis/spindle standstill
Reset
67000–67999 Display Cancel
68000–69000 Reserved
70000–79999 Compile cycle alarms
400000–499999 PLC alarms, general
500000–599999 PLC alarms for channel
600000–699999 PLC alarms for axis and
spindle
700000–799999 PLC alarms for user
800000–899999 PLC alarms for sequential
controllers/graphs
The text file for cycle and compile cycle alarms has the following structure:
Table 11-3 Structure of text file for cycle alarm texts
Alarm number Display Help ID Text or alarm number
60100 1 0 “No D number %1 programmed”
60101 1 0 60100
... ... ... ...
65202 0 1 “Axis %2 in channel %1 is still moving”
// Alarm text file for cycles in German
References: /FB/, Description of Functions, Basic Machine
P3 Basic PLC Program
Section: Lists
Alarm number list
This number defines the alarm display type:
0: Display in alarm line
1: Display in a dialog box
Alarm numbers
Format of the
text file for
cycle alarm texts
Alarm number
Display