15.3 Data backup
15-486
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
15.3.4 Restoring the hard disk backup using a network link (Ethernet)
The operating actions explained in the following are intended to make a backup
copy of the entire hard disk of the PCU (disk image) and to restore it from an
external computer (PG/PC) using a network connection.
For data transfer, a local point-to-point connection between the external com-
puter and the PCU is established using the standard Ethernet cable of the type
“Twisted Pair Crossed
10baseT/100baseTX Ethernet Cable”.
The following requirements must be fulfilled:
S The operating system of the external computer is
Windows NT 4.0
Windows 95.
S The Ethernet cable is connected to the Ethernet interface of the external
computer and the PCU.
Notice
A point-to-point connection between PCU 50 and an external computer
(PG/PC) requires an Ethernet cable of the type “Twisted Pair Crossed
10ba-
seT/100baseTX Ethernet Cable”.
S The network parameters of the external computer are set or known:
Network Protocol NetBEUI
Computer Name
Shared As.
How to set or determine the network parameters of an external computer is de-
scribed in Subsection 15.1.4 (page 15-458).
After the PCU has been turned on, the menu of the boot manager is displayed.
1. Choose the menu item Service Menu (hidden).
The following menu will appear:
Brief description
Requirements
Operating actions
15 SW Installation/U