06.03
10.4 Memory configuration
10-302
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
2. Virtual Memory
Windows NT start bar: Start > Settings > Control Panel > System > Per-
formance > Virtual Memory
System Properties
OK
SINUMERIK 840Di NCK/PLC
Drive: [Volume Label] Paging File Size [MB]
Drive: E: [WinNT]
Total Paging File Size for All Drives
Registry Size
Space Available: 560 MB
Initial Size [MB]: 135 MB
Maximum Size [MB]: 200 MB
Minimum Allowed: 2 MB
Recommended: 75 MB
Currently Allocated: 135 MB
Current Registry Size: 10 MB
Maximum Registry Size [MB]: 13
Set
Help
Cancel
Paging File Size for Selected Drives
C: [DOS]
D: [TMP]
E: [WinNT] 135 – 200
F: [840DSystem]
Fig. 10-5 Dialog: Windows NT system settings
The following setting must be made:
The size of the Paging Files set (“Paging File Size [MB]”) on the Win-
dows NT drive ( E: [WinNT] )must correspond at least
(“Initial Size [MB]”)
to the size of the main memory of the PCU.
If settings are incorrect, the following message box appears:
OK
SINUMERIK 840Di NCK/PLC
Alarm: Increase “Initial Size” of pagefile to at least 128 MB.
10 NC Start-U
p
with HMI Advanced