A.8 Information List
553
7SA522 Manual
C53000-G1176-C155-3
401 >S MIN/MAX Buffer Reset (>S
MiMa Reset)
Min/Max meter SP ON * * LED BI BO
402 >Q MIN/MAX Buffer Reset (>Q
MiMa Reset)
Min/Max meter SP ON * * LED BI BO
403 >Idmd MIN/MAX Buffer Reset
(>Idmd MiMaReset)
Min/Max meter SP ON * * LED BI BO
404 >Pdmd MIN/MAX Buffer Reset
(>Pdmd MiMaReset)
Min/Max meter SP ON * * LED BI BO
405 >Qdmd MIN/MAX Buffer Reset
(>Qdmd MiMaReset)
Min/Max meter SP ON * * LED BI BO
406 >Sdmd MIN/MAX Buffer Reset
(>Sdmd MiMaReset)
Min/Max meter SP ON * * LED BI BO
407 >Frq. MIN/MAX Buffer Reset
(>Frq MiMa Reset)
Min/Max meter SP ON * * LED BI BO
408 >Power Factor MIN/MAX Buffer
Reset (>PF MiMaReset)
Min/Max meter SP ON * * LED BI BO
410 >CB1 aux. 3p Closed (for AR,
CB-Test) (>CB1 3p Closed)
P.System Data 2 SP * * * LED BI BO 150 80 1 Yes
411 >CB1 aux. 3p Open (for AR, CB-
Test) (>CB1 3p Open)
P.System Data 2 SP * * * LED BI BO 150 81 1 Yes
501 Relay PICKUP (Relay PICKUP) P.System Data 2 OUT * * m LED BO 128 84 2 Yes
503 Relay PICKUP Phase L1 (Relay
PICKUP L1)
P.System Data 2 OUT * * m LED BO 128 64 2 Yes
504 Relay PICKUP Phase L2 (Relay
PICKUP L2)
P.System Data 2 OUT * * m LED BO 128 65 2 Yes
505 Relay PICKUP Phase L3 (Relay
PICKUP L3)
P.System Data 2 OUT * * m LED BO 128 66 2 Yes
506 Relay PICKUP Earth (Relay
PICKUP E)
P.System Data 2 OUT * * m LED BO 128 67 2 Yes
507 Relay TRIP command Phase L1
(Relay TRIP L1)
P.System Data 2 OUT * * m LED BO 128 69 2 No
508 Relay TRIP command Phase L2
(Relay TRIP L2)
P.System Data 2 OUT * * m LED BO 128 70 2 No
509 Relay TRIP command Phase L3
(Relay TRIP L3)
P.System Data 2 OUT * * m LED BO 128 71 2 No
510 Relay GENERAL CLOSE
command (Relay CLOSE)
P.System Data 2 OUT * * * * LED BO
511 Relay GENERAL TRIP
command (Relay TRIP)
P.System Data 2 OUT * OFF m LED BO 128 68 2 No
512 Relay TRIP command - Only
Phase L1 (Relay TRIP 1pL1)
P.System Data 2 OUT * * * LED BO
513 Relay TRIP command - Only
Phase L2 (Relay TRIP 1pL2)
P.System Data 2 OUT * * * LED BO
514 Relay TRIP command - Only
Phase L3 (Relay TRIP 1pL3)
P.System Data 2 OUT * * * LED BO
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Inputs
Function Key
Relay
Chatter suppression
Type
Information Number
Data Unit
General Interrogation