Commissioning
4.4 Establishing an online connection to the drive
Commissioning with Startdrive
Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
103
Displaying and deleting temporary IP addresses
You can display and also delete all temporarily assigned addresses.
1. Navigate in the project navigator under "Online access" to the appropriate interface.
2. In the shortcut menu, click "Properties".
3. Under Configuration, select the "IE-PG Access" item.
Figure 4-42 Displaying and deleting temporary IP addresses
Restoring factory settings
Restoring factory settings
If problems occur during the commissioning via PROFINET, it is recommended that the IP
settings of the drive be restored to the factory settings. This provides a defined basis for an
error-free commissioning.
An online connection has been established to the drive.