Commissioning
4.5 Commissioning a drive
Commissioning with Startdrive
Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
105
4.5
Commissioning a drive
4.5.1
Using the control panel
From the drive control panel (see also the overview in Chapter "Drive control panel
(Page 43)") operate the drive and test the settings that have already been made.
WARNING
Risk of death if the safety instructions for the drive control panel are not carefully complied
with
The safety shutdowns from the higher-level controller have no effect with this function. The
"Stop with space bar" function
is not guaranteed in all operating states. Incorrect operation
by untrained personnel without taking into account the appropriate safety instructions
can therefore result in death or severe injury.
Make sure that this function is only used for commissioning, diagnostic and service
purposes.
Make sure that this function is only used by trained and authorized skilled personnel.
Make sure that a hardware device is always available for the EMERGENCY OFF circuit.
Note
Drive reacts immediately
Although all enables are removed before returning the master control, the setpoints and
commands still come from the original parame
terized sources after the master control is
returned.
Precondition
Startdrive is in the online mode (Page 90).

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals