Dual enclosure Re󹪞ect mount wiring
Referring to the Hi Precision single enclosure re󹪞ect mount 󹪝gure above, connect the Hi
Precision mount re󹪞ect Dual enclosure sensor cables from the transmitter ports as follows:
1. Observing the upstream and downstream orientation , connect sensor cables from
transmitter ports.
2. Tighten all cable glands to obtain optimum sealing.
3. Refer to transmitter FST030 Operating Instructions to program transmitter.
Dual enclosure direct mount wiring
Connect sensor cables to the DSL and transmitter as follows:
1. Fill connector end with Super Lube prior to connecting.
2. Apply Super Lube to the internal threads at the large end of the thread connector.
3. Observing the upstream and downstream orientation , connect upstream sensor cable
from transmitter port (1A) and make connection snug.
Connecting
4.4HI Precision mount FST030
SITRANS FS130 & FS230
44 Compact Operating Instructions, 12/2023, A5E38755607-AF