Channel 2 current output settings
Table A-50 Channel 2 current output settings
Modbus
register
Data type /
Size in bytes
Parameter Description Default value
[units]
(units register)
Value range /
Setting options
Access
level
8802 Unsigned / 2 Process value Select process value
for the current output.
-
0: Mass flow
1: Volume flow
2: Density
3: Medium
temperature
18: Sound velocity
19: Flow velocity
20: Pressure
21: Viscosity
22: RTD temperature
1
23: RTD temperature
2
24: Medium
concentration
25: Measured current
(Channel 5)
26: Measured current
(Channel 6)
27: Standard volume
flow rate (only
hydrocarbon and gas
applications)
28: Standardizing
factor (only
Read /
write
Modbus communication
A.9 Modbus holding registers tables
SITRANS FST030 (Modbus)
200 Operating Instructions, 08/2018, A5E37367739-AD