48
EN
1.6 Fault / malfunction codes
If a fault/malfunction is detected during boiler operation, the
message
"E"
will appear on the display followed by the fault
code.
If you see alarm
“04”
(low water pressure in the system):
using a pressure gauge (1), check that the heating system
pressure when cold is
1-1.2 bar
. If this is not the case, open
the filling valve (2) and restore the heating system pressure
until the pressure gauge (1) shows a reading of
1-1.2 bar
close the filling valve (2)
turn dial
t
to
6
/
R
and then again to the adjustment value
required. This resets normal operating conditions.
21
Fig. 8
If you see alarm
“E01”
(no flame detected):
turn dial
t
to
6
/
R
and then again to the adjustment value
required. This resets normal operating conditions.
OFF
RESET
Fig. 9
If this operation is not successful,
ONLY ONE MORE RESET
ATTEMPT
can be made, therefore:
close the gas isolation valve
set the main system switch to "OFF"
contact the Qualified Technical Personnel.
OFF
Fig. 10
m
CAUTION
Should you see an alarm not described here, contact a
qualified technical professional
.
2 SHUTDOWN
2.1 Temporary shutdown
If the boiler is to be left unused for a long period, the following
operations need to be carried out::
turn dial
t
to
6
/
R
. The display will show
"- -"
. If an
external sensor is connected, the display will show icon
3
and the value of the external temperature detected.
OFF
RESET
Fig. 11
f
ELECTRICAL HAZARD
The boiler will still be powered.
If the user is away temporarily (for a weekend, short trip etc)
and if the outside temperature is at ZERO:
turn dial
t
to
6
/
R
set the main system switch to "OFF"
close the gas valve.
OFF
RESET
OFF
Fig. 12
m
CAUTION
If the outside temperature might fall below ZERO,
since the appliance is equipped with an "antifreeze
function"
turn dial
t
to
6
/
R
leave the main system switch set to "ON" (boiler is
powered)
leave the gas valve open.
ON
Fig. 13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sime GO 18 BF and is the answer not in the manual?

Sime GO 18 BF Specifications

General IconGeneral
BrandSime
ModelGO 18 BF
CategoryBoiler
LanguageEnglish

Related product manuals