EasyManuals Logo

Sime GO 18 BF User Manual

Sime GO 18 BF
Go to English
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
54
EN
5.5 Technical features
DESCRIPTION
GO 18 BF GO 25 BF GO 30.BF
CERTIFICATIONS
Country of intended installation AZ - BY - CL - DZ - GE - IL - MA - MK - RS - RU - TN - UA - UZ
Fuel G20 - G30/G31
PIN number 431M
Category II2H3+
Type
B22P - B52P - C12 - C12X - C32 - C32X - C42 - C42X - C52 - C52X - C62 -
C62X - C82 - C82X - C92 - C92X
Class NO
x
3 (< 150 mg/kWh)
HEATING PERFORMANCE
HEAT INPUT
Nominal kW 20,5 25,5 28,5
Minimum (G20-G30/G31) kW 5,5 - 6,0 9,2 - 9,2 10,5 - 10,5
HEAT OUTPUT
Nominal (80-60°C) kW 19,0 23,5 26,2
Minimum (80-60°C) (G20-G30/G31) kW 4,5 - 4,9 7,6 - 7,6 8,7 - 8,7
EFFICIENCY
Max useful efficiency (80-60°C) % 92,6 92,0 92,0
Min useful efficiency (80-60°C) % 82,3 83,1 83,3
Useful efficiency at 30% of load (50-37°C) % 89,4 89,7 89,6
Losses after shutdown at 50°C W 79 81
DOMESTIC HOT WATER PERFORMANCE
Nominal heat input kW 20,5 25,5 28,5
Minimum heat input (G20-G30/G31) kW 5,5 - 6,0 9,2 - 9,2 10,5 - 10,5
D.H.W. flow rate ∆T 30°C (EN 13203) l/min 8,9 10,6 12,2
Continuous D.H.W. flow rate (∆T 25°C / ∆T 35°C) l/min 10,9 / 7,8 13,1 / 9,3 15,0 / 10,5
Minimum D.H.W. flow rate l/min 2,2
Max / Min Pressure
bar 7 / 0,4
kPa 700 / 40
ELECTRICAL SPECIFICATIONS
Power supply voltage V 230
Frequency Hz 50
Absorbed electrical power W 110 120
Electrical protection degree IP X5D
COMBUSTION DATA
Smoke temperature at Max/Min flow (80-60°C) °C 119,3 / 90,2 153,8 / 116,3 159,0 / 117,2
Smoke flow Max/Min g/s 13,8 / 13,4 16,9 / 17,2 18,9 / 20,6
CO
2
at Max/Min (G20) flow rate with separate chimneys
(*)
% 6,2 / 1,6 6,3 / 2,1 6,3 / 2,0
CO
2
at Max/Min (G30/G31) flow rate with separate
chimneys (*)
% 6,7 / 1,8 7,3 / 2,3 7,6 / 2,5
CO
2
at Max/Min (G20) flow rate with concentric
chimneys (**)
% 5,8 / 1,5 6,2 / 2,0 6,3 / 2,0
CO
2
at Max/Min (G30/G31) flow rate with concentric
chimneys (**)
% 6,5 / 1,8 7,4 / 2,3 7,7 / 2,4
NOx measured mg/kWh 109 123 122
NOZZLES GAS
Number of nozzles No. 11 12
Nozzle diameter (G20-G30/G31) mm 1,13 - 0,70 1,30 - 0,80 1,30 - 0,80
Gas consumption at Max/Min flow rate (G20) m
3
/h 2,17 / 0,58 2,70 / 0,97 3,02 / 1,11
Gas consumption at Max/Min flow rate (G30) kg/h 1,62 / 0,47 2,01 / 0,72 2,25 / 0,82
Gas consumption at Max/Min flow rate (G31) kg/h 1,59 / 0,46 1,98 / 0,71 2,21 / 0,81
Gas supply pressure (G20/G30/G31)
mbar 20 / 28-30 / 37
kPa 2 / 2,8-3 / 3,7
TEMPERATURE PRESSURE
Max operating temperature °C 85
Heating adjustment range °C 20 ÷ 80
Domestic hot water adjustment range °C 37 ÷ 60
Max operating pressure
bar 3
kPa 300
Water content in boiler l 3,05
(*) With minimum chimney length
(**) With maximum chimney length
Lower Heat Output (Hi)
G20 Hi.
9.45 kW/m
3
(15°C, 1013 mbar) -
G30 Hi.
12.68 kW/kg (15°C, 1013 mbar) -
G31 Hi.
12.87 kW/kg (15°C, 1013 mbar)