EasyManuals Logo

Sime GO 18 BF User Manual

Sime GO 18 BF
Go to English
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
60
EN
6 INSTALLATION
m
CAUTION
The appliance must only be installed by the
Sime
Technical Service or by qualified professionals
who
MUST wear
suitable protective safety equipment.
6.1 Receiving the product
GO BF
appliances are delivered in a single unit protected by
cardboard packaging.
Fig. 22
The plastic bag found inside the packaging contains the
following:
Installation, use and maintenance manual
Paper template for boiler installation
Hydrostatic test certificate
Export documentation for Russia
Diaphragm
Bag with expansion plugs
d
IT IS FORBIDDEN
Do not leave packaging material around or near
children since it could be dangerous. Dispose of it as
prescribed by legislation in force.
6.2 Dimensions and weight
H
L
P
Fig. 23
Description
GO BF
18 25 30
W (mm) 420
D (mm) 255
H (mm) 700
Weight (kg) 28 28,5
6.3 Handling
Once the packaging has been removed, the appliance is to
be handled manually, tilting it slightly, lifting it and applying
pressure in the points indicated in the figure.
Fig. 24
d
IT IS FORBIDDEN
To grip the appliance casing. Hold the "solid" parts of
the appliance such as the base and structural frame.
a
WARNING
Use suitable tools and accident protection when
removing the packaging and when handling the
appliance. Observe the maximum weight that can be
lifted per person.
6.4 Installation room
The room where the appliance is to be installed must comply
with the Technical Regulations and Legislation in force. It must
be equipped with suitably sized ventilation openings when the
installation is a "TYPE B" installation.
The minimum temperature of the installation room must NOT
be lower than
-5 °C
.
m
CAUTION
Before assembling the appliance, the installer
MUST
make sure that the wall supports the weight.
Remember to consider the space needed in order to
access the safety/adjustment devices and to carry
out maintenance interventions (see Fig. 25).