9. Position the Sensitive element on the Horizontal ring by
putting the assembly jigs into the holes as indicated on the
figure below. Observe the rings on the jigs to ensure proper
positioning. Insert and fasten the two screws in the other
holes.
ASSEMBLY JIG
WITH 1 CIRCLE
ASSEMBLY JIG
WITH 2 CIRCLES

Table of Contents

Other manuals for Simrad GC80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad GC80 and is the answer not in the manual?

Simrad GC80 Specifications

General IconGeneral
TypeGyro Compass
Power Supply24 V DC
Operating Temperature-15°C to +55°C
Heading Resolution0.01°
Heading Repeatability±0.1°
IP RatingIP66
Storage Temperature+70°C
InterfacesNMEA 0183
Humidity95% non-condensing