Simrad GC80/GC85 Dual Gyro Compass
60 20221537 / D
5 Press the DISP button again to select sub-category 1.2.F,
and use the arrow buttons to increase or decrease the
parameter value until the value corresponds with the
parameter for the new sensitive element. Confirm the entry
by pressing the ACK/ENT button.
6 Repeat step 5 for sub-category 1.3.S, 1.4.u, 1.5.L and
1.6.t.
7 Press the SET button again to return to main category A1,
and then press the DISP button to go to A2 main category.
8 Press the SET button, and enter values for 2.1.o and 2.3.h
as described above.
9 While still in A2 main category, enter values for 2.5.y
(Year), 2.6.N (Month and Day), 2.7.t (Hour and Minute)
and 2.8.d (total days of operation. This value should be
reset after installation).
Note! All time parameters should preferably be in CET (Central
European Time) or eventually in local time.
10 Press the
SET button again to return to main category A2,
and then press the DISP button until main category A7 is
displayed.
11 Exit the sub-category by pressing the
SET button, and then
exit the Extension main category by pressing and holding
the
SET and ACK/ENT buttons simultaneously for at appr.
3 seconds.
For more information about the Extension menu, see
ADVANCED SETTINGS, page 67 onwards.

Table of Contents

Other manuals for Simrad GC80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad GC80 and is the answer not in the manual?

Simrad GC80 Specifications

General IconGeneral
TypeGyro Compass
Power Supply24 V DC
Operating Temperature-15°C to +55°C
Heading Resolution0.01°
Heading Repeatability±0.1°
IP RatingIP66
Storage Temperature+70°C
InterfacesNMEA 0183
Humidity95% non-condensing

Related product manuals