• -Insertthecablesofthemainrotorintheexciterrotor
• Inserttheexciterrotor(byhand,orwiththehelpofa
rubberhammer)
• Insertthescrew(2),screwitintothetab(withthread
lock)andtightenitfollowingthetorquevaluesshown
inparagraph6.2.4
• Reconnectthediodebridgeobservingthepolarities
• Replacethebearingshieldandprotectivegrid.
8. CLEANING AND LUBRICATION
Makesurethatthegeneratingsetisshutdownandthe
mainspowerisshutoffbeforecleaningtheoutsideof
thegeneratingsetwithcompressedair.
9. DISMANTLING AND DISPOSAL
All material should be eliminated in compliance with
statutoryregulations.
The generator does not present any particular risks
orhazardsduring dismantling.Toaid recovery of the
material,itisbest toclassifyitbytype(i.e.electrical
parts,copper,aluminium,plastic,etc.).
Anykindofcleaningworkmustbecarried
outwiththegeneratingsetshutdownand
the mains power shut o󰀨 for the risk of
severehazardforpersonsandobjects.
Onlyuseauthorisedspecialists.
Neverandfornoreasonwhatsoeveruse
uids or water. Do not use compressed
airtoclean internal electricalparts since
this could cause short circuits or related
problems.
WARNING!
WARNING!
WARNING!
2
1
FAN
2
1
ROTOR
EXCITER