9. Monitoring and maintenance
EN
9. Monitoring and maintenance
Impurities in the lubricant may cause the
pump unit or dosers to malfunction or dam-
age lubrication points.
The pump unit is equipped with a filter
(Figure 7 item A) to prevent impurities from
entering the system. The filter must be
cleaned twice a year. A good indication of a
clogged filling filter is that filling takes longer
than usual.
9. System monitoring and maintenance
After cleaning the filter, fill the filter housing
with grease and place the filter back in its
place.
Lubricant pipes or hoses from dosers to
lubrication points run unshielded in areas
and are exposed to damage. Check daily that
the pipes or hoses are intact and lubricant
reaches all lubrication points.
When the system has been operational for
some weeks, you should check again all lu-
brication points.
If required, the lubrication interval can be
increased or decreased from the ST102
control centre. This adjustment should be
conducted after several weeks or months,
finally finding the exact lubricant volume for
all operating conditions.