Section 5 – Procedures Deutz Diesel Engines
Standstill Regeneration Stages
Standstill
Lamps
3 4
Engine
Lamp
5
Audible
Alarm
6
Engine
Torque
Action Required
Flashes slowly Off
Pulsates
slowly
100%
Do the standstill operation at the next available
opportunity, within 3 to 4 hours.
Flashes slowly On
Pulsates
slowly
75% Do the standstill operation immediately.
Flashes quickly
Flashes
Pulsates
quickly
40%
a. The standstill operation is no longer possible with
on-machine controls.
Contact an authorized repair facility.
b. Failure to do the standstill has caused diesel
particulate filter failure, and regeneration is no
longer possible. Contact an authorized repair facility
to replace the filter.
Do the Standstill Regeneration
1. Move the MEWP to an open, well-ventilated
area, away from any flammable material. Park it
on a firm level surface, and fully stow the MEWP.
2. While the engine runs, turn the off/base/platform
switch
7
on the base controls to the base
position.
3. Move the standstill switch
8
on the base
controls to the right to start the standstill
regeneration. The base functions will not operate
while the standstill switch is turned on.
4. On the engine display module
2
press
and hold the middle button
9
(below the
regeneration symbol) for 7 seconds.
WARNING
Do not touch hot engine components. Serious
injury can occur if you touch hot surfaces.
5. The engine display module changes to the
Regeneration Ongoing symbol
10
, the standstill
lights illuminate continuously, and the engine
speed can change.
6. Standstill regeneration takes approximately
45 minutes. During this time you must not use
the MEWP.
IMPORTANT
Complete the standstill regeneration fully. If
you interrupt the process, the standstill request
continues.
7. When the standstill regeneration is complete,
the Regeneration Ongoing symbol changes to
Regeneration Complete
11
, the standstill lights
3 4
go off, and the engine speed goes back to
normal.
8. Move the standstill switch to the left. You can use
the MEWP normally.
IMPORTANT
Only use the standstill regeneration override
switch
12
on the front of the platform control box
when absolutely necessary to move the MEWP to
park it in a safe location when the derated engine
torque/rpm prevents sufficient torque to drive the
MEWP.
It temporarily (for approximately 30 minutes)
restores full engine power and speed.
Use of the derate override switch can cause diesel
particulate filter failure.