EasyManuals Logo

Skyjack SJ82 T Service Manual

Skyjack SJ82 T
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #240 background imageLoading...
Page #240 background image
245
SJ82 T, SJ86 T
229040ABA
Manifolds and Hydraulic Pumps Section 5 – Procedures
5.8-2 Hydraulic Standby Pressure
Adjustment
1. Locate the GP2 port
1
on either the top or
bottom of the main manifold and remove the
cap.
Main Manifold and Pressure Gauge
2. Connect a pressure gauge (600 psi) to the GP2
port.
3. Start the ngine from the base control console
and let it run for 2-5 minutes.
4. Check the reading on the gauge (standard
pressure should be 330 psi) and follow the next
steps for adjusting pressure if needed.
5. Locate the load sense compensator
2
on the
system pump.
6. Loosen the lock nut.
7. Adjust the load sensing pressure by turning
the adjusting stem either clockwise to increase
pressure or counterclockwise to decrease
pressure.
8. Tighten the lock nut after pressure is set to 330
psi.
9. Turn the engine off.
10. Remove the pressure gauge from the GP2 port
and cap the port.
2
1
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ82 T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ82 T and is the answer not in the manual?

Skyjack SJ82 T Specifications

General IconGeneral
BrandSkyjack
ModelSJ82 T
CategoryBoom Lifts
LanguageEnglish

Related product manuals