180
SJ85 AJ229044ADA
Section 5 – Procedures Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code Error Identification
791 411 0 6-9-3 Delta pressure across venturi in EGR line above physical high limit.
793 411 0 6-9-3
Plausibility Check fault for deviation of desired and actual EGR-mass flow,
where the latter is calculated out of EGR Delta Pressure Sensor.
795 411 3 6-9-3 Sensor error differential pressure Venturiunit (EGR), signal range check low.
796 411 4 6-9-3 Sensor error differential pressure Venturiunit (EGR), signal range check high.
805 524025 14 8-4-5
Particulate filter regeneration.
(3x) over the max. has been aborted allowed recovery time.
Regeneration after time X is not successful (the error occurs when the
regeneration times).
806 524058 2 8-4-4 Particulate filter; regeneration not succesful.
807 3253 2 6-9-2 Differential pressure DPF, plausibility error.
809 3251 0 6-9-2 Differential pressure DPF maximum value is exceeded.
810 3251 0 6-9-2 Differential pressure sensor across DPF exceeds warning high limit.
812 3251 1 6-9-2 Differential pressure DPF, pressure below lower shutoff threshold.
813 3251 1 6-9-2 Differential pressure DPF, pressure below lower warning threshold.
814 3253 3 6-9-2 Electrical error differential pressure B58 (DPF). (Signal range check high).
815 3253 4 6-9-2 Electrical error differential pressure (DPF). signal range check low.
825 523009 9 2-5-3
The pressure relief valve (PRV) has reached the number of allowed
activations.
826 523470 2 1-4-6 Pressure relief valve is forced to open, perform pressure increase.
827 523470 2 1-4-6 Pressure Relief Valve (PRV) forced to open. Performed by pressure increase.
828 523470 12 1-4-6 Pressure Relief Valve (PRV) forced to open. Shutoff conditions.
829 523470 12 1-4-6 Pressure Relief Valve (PRV) forced to open. Warning conditions.
830 523470 14 1-4-6 Open Pressure Relief Valve (PRV).
831 523470 11 1-4-6 Pressure Relief Valve (PRV) error; Rail pressure out of tolerance range.
832 523470 11 1-4-6
Rail pressure out of tolerance range.
The PRV can not be opened at this operating point with a pressure shock.
833 523009 10 2-5-3
Open time of Pressure Relief Valve (PRV) for wear out monitoring had
exceeded.
834 523906 5 7-6-1 Electrical fuel pre - supply pump; open load.
835 523906 12 7-6-1 Electrical fuel pre - supply pump. ECU powerstage over temperature.
836 523906 3 7-6-1 Electrical fuel pre - supply pump; short circuit to battery.
837 523906 4 7-6-1 Electrical fuel pre - supply pump. Short circuit to ground.
847 1176 0 1-3-9 Pressure sensor upstream turbine, Physical Range Check high.
848 1176 1 1-3-9 Pressure sensor upstream turbine, Physical Range Check low.
849 1176 3 1-4-1 Pressure sensor upstream turbine, signal range check (SRC) high.
850 1176 4 1-4-1 Pressure sensor upstream turbine, signal range check (SRC) low.
856 523613 0 1-3-4 Rail pressure metering unit, Positive governor deviation.
1513AA-10
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ85 AJ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ85 AJ and is the answer not in the manual?

Skyjack SJ85 AJ Specifications

General IconGeneral
BrandSkyjack
ModelSJ85 AJ
CategoryBoom Lifts
LanguageEnglish

Related product manuals