26
Section 1 – Scheduled Maintenance Scheduled Maintenance Inspections
1.6-7 Platform Assembly
1 2
Railings and gates
▪
Make sure there are no loose or missing parts,
and there is no visible damage.
▪
Make sure the fasteners are correctly installed.
▪
Make sure the platform railings
1
are in the
correct position.
▪
Make sure the gates or drop bars
2
are in
good condition and operate correctly.
3
MEWP floor
▪
Make sure the MEWP floor is solid and there is
no visible damage.
4
Footswitch
▪
Make sure the footswitch is in good working
order and has not been tampered with,
disabled or blocked.
5
Fall-protection anchorages
▪
Make sure that the fall-protection anchorages
are correctly installed.
▪
Make sure there is no visible damage.
6
AC power socket
▪
Make sure that the socket is free of dirt or
blockages.
7
Platform control console (B)
▪
Make sure all switches and controllers are in
the neutral position.
▪
Make sure there are no loose or missing parts,
and there is no visible damage.
8
Manual storage box (B)
▪
Make sure that the operation manual and
other important documents are in the manual
storage box.
▪
Make sure that the documents are in good
condition, and you can read them.
▪
Always put the manuals and other documents
back in the storage box after use.
9
Load Cell (B)
▪
Make sure there are no loose or missing parts,
and there is no visible damage.
▪
Make sure the fasteners are correctly installed.
▪
Make sure the cables are in good condition.
▪
Make sure the cable connections are tight.
▪
Make sure there is no debris lodged between
the platform and the boom adaptor.
9
8
5
7 6
4
3
2
1
2