5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code Error Identification
916 523721 2 6-8-9 Sensor DEF supply module temperature; plausibility error (normal condition).
917 523721 2 6-8-9
Sensor DEF supply module temperature; plausibility error (cold start
condition).
918 523981 11 2-4-3
SCR plausibility, OBD and diagnosis; Stuck in range check of DEF tank
temperature sensor.
DEF-tank without heating function (heating phase).
919 523330 14 1-3-1 Immobilizer status; fuel blocked.
920 523330 14 1-3-1 DFC to block the fuel by Sia. No detailed information!
921 523330 14 1-3-1
DFC to indicate that TEN-code or UC-code received if ECU is learned.
No detailed information!
922 523330 14 1-3-1 DFC to indicate that no code is received via CAN. No detailed information!
923 523330 14 1-3-1 DFC to indicate that wrong code is received. No detailed information!
925 523720 8 1-4-8 DEF supply module heater temperature; duty cycle in failure range.
926 523720 8 1-4-8 DEF supply module heater temperature; duty cycle in invalid range.
927 523721 11 6-8-9 Urea supply module temperature measurement not available.
928 523722 8 6-9-1 DEF supply module PWM signal; period outside valid range.
929 523722 8 6-9-1 Detect faulty PWM signal from Supply Modul.
930 523721 8 6-8-9 DEF supply module temperature; duty cycle in failure range.
931 523721 8 6-8-9 Urea supply module temperature; duty cycle in invalid range.
932 29 3 1-2-6 Handthrottle idle validation switch; short circuit to battery
935 91 3 2-2-6 Sensor error accelerator pedal. signal range check high.
937 29 4 1-2-6 Handthrottle; short circuit to ground.
940 91 4 2-2-6 Sensor error accelerator pedal. Signal is below the range.
942 523921 3 7-1-4 Sensor error burner temperature; signal range check high.
943 3532 3 1-2-7 Sensor error DEF tank level; signal range check high.
944 523921 4 7-1-4 Sensor error burner temperature; signal range check low.
946 1079 13 2-8-2 Failure of sensor supply voltage 1.
947 1080 13 2-8-2 Failure of sensor supply voltage 2.
948 523601 13 2-8-2 Failure of sensor supply voltage 3.
956 677 3 5-1-2 Starter relay high side. Short circuit to battery.
957 677 4 5-1-2 Starter relay high side short circuit to ground.
958 677 5 5-1-2 Starter relay low side no load error.
959 677 12 5-1-2 Starter relay powerstage over temperature.
960 677 3 5-1-2 Starter relay low side short circuit to battery.
961 677 4 5-1-2 Starter relay low side short circuit to ground.
965 523922 3 7-1-5 Burner shut of valve; short circuit to battery.
969 624 5 5-1-3 SVS lamp; open load.
1513AA-12
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ85 AJ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ85 AJ and is the answer not in the manual?

Skyjack SJ85 AJ Specifications

General IconGeneral
BrandSkyjack
ModelSJ85 AJ
CategoryBoom Lifts
LanguageEnglish

Related product manuals