-85-
No.EX※※-OMX1011
A mapping example is shown below when the process data mapping is set to port 2 byte
Input data
Output data
Byte 0
X2
X4
X2
X4
X2
X4
X2
X4
-
Y4
-
Y4
-
Y4
-
Y4
Port 4
Port 3
Port 2
Port 1
Port 4
Port 3
Port 2
Port 1
Byte 1
(fixed value: 0)
(fixed value: 0)
Byte 2
Port 1 process data
Port 1 process data
Byte 3
Port 1process data
Port 1 process data
Byte 4
Port 2 process data
Port 2 process data
Byte 5
Port 2 process data
Port 2 process data
Byte 6
Port 3 process data
Port 3 process data
Byte 7
Port 3 process data
Port 3 process data
Byte 8
Port 4 process data
Port 4 process data
Byte 9
Port 4 process data
Port 4 process data
Byte 10
:
Byte 39
(fixed value: 0)
(fixed value: 0)
Byte 40
Port 1 status (PQI)
(fixed value: 0)
Byte 41
Port 2 status (PQI)
(fixed value: 0)
Byte 42
Port 3 status (PQI)
(fixed value: 0)
Byte 43
Port 4 status (PQI)
(fixed value: 0)