- 54 -
10.4 Initial setting value of LEY series
Initial setting value of LEY series.
Refer to the table below for initial setting of Return to origin, jog and inching.
Common for all series of LEY
Direction Side to be retracted
speed [mm/s] 20
Return to home
origin
acceleration [mm/s
2
] 1000
speed [mm/s] 10
Jog
acceleration [mm/s
2
] 1000
Inching Distance[mm] 1
Refer to the table below for the set value for 3 levels of pushing force and the pushing speed. Pushing
speed is fixed.
LEY16 LEY25 LEY32
A B C A B C A B C
Low 14 27 51 63 126 232 80 156 296
Middle 26 50.5 96 92.5 182 342 134.5 263 501.5
Pushing
force [N]
High 38 74 141 122 238 452 189 370 707
Pushing speed [mm/s] 15 8 4 18 9 5 24 12 6
*Pushing force accuracy is ±20%F.S. Refer to the operation manual of the actuator for details.
Refer to the table below for the speed and the acceleration table of the LEY series.
LEY16A LEY16B LEY16C
speed
[mm/s]
acceleration
[mm/s
2
]
speed
[mm/s]
acceleration
[mm/s
2
]
speed
[mm/s]
acceleration
[mm/s
2
]
0 15 200 8 200 4 200
1 20 300 10 300 6 300
2 30 400 15 400 8 400
3 40 500 20 500 10 500
4 50 600 25 600 13 600
5 60 700 30 700 15 700
6 80 800 40 800 20 800
7 100 900 50 900 25 900
8 150 1000 75 1000 38 1000
9 200 1200 100 1200 50 1200
10 250 1400 125 1400 63 1400
11 300 1600 150 1600 75 1600
12 350 1800 175 1800 88 1800
13 400 2000 200 2000 100 2000
14 450 2500 225 2500 113 2500
15 500 3000 250 3000 125 3000