60 PRO-LINK
®
Edge Hardware and Software User’s Manual
Chapter 4 • Using the Diagnostics Menu
Each fault listed contains the following information for that fault:
Line Number
Contents
1 The name of the module where the fault was
found (e.g., Engine 1 - Paccar)
2 Either the name of the parameter experienc-
ing the fault, or a combination of the name
and a descript
ion
of the fault (e.g., Inlet air
pressure in inlet manifold - Voltage too low or
short circuit to ground - on ECU (D420) pin
(A51).
3 SAE/DTC information about the fault (e.g.,
DTC P0101 - Powertrain (P) - Current)
Viewing More Info
You can view more information on a particular fault (e.g., Freeze Frame Data and
PRO-LINK
®
Repair-Connect troubleshooting information) by touching the fault to
display the More Info screen.
To view more information on a particular fault:
1 Touch the screen to select the fault for which you want to view more informa-
tion (e.g., Inlet air pressure in
inlet manifold).

Table of Contents