12.1.4. Input/output specications HMI
Digital inputs/outputs – ISOM Digiware L-60
Number of inputs
4
Type / Power supply Output: 12-24VDC min 600Ω 40 mA max
Input: Max 100 Ω
Insulated input, internal polarisation, dry contact (default impedance max
100Ω) - SELV in accordance with IEC61010
Input functions Logical status (state of the circuit breaker: position, trigger, drawer)
TEST, external RESET, stop measurement, start measurement
Output functions
Configurable alarm on breach of threshold 3A
Connection Removable spring-cage terminal block, 6 positions - 4 dedicated to outputs,
1 input polarisation, 1 common output point, stranded or solid 0.2-1.5mm²
cable
Relay outputs – ISOM Digiware L-60
Number of outputs
2
Type Changeover switch
Rated voltage AC: 250 V
Rated voltage DC: 30 V
Sustained current: 3 A
Operating mode: standby/working
Default operating mode: standby
Output functions
Alarm
Connection
0.2 - 2.5 mm
2
PTC inputs – ISOM Digiware L-60
Number of inputs
1
Type / Power supply Logical status (temperature sensor)
Analogue input: PTC probe
Input functions
Alarm
Connection
0.2 - 2.5 mm
2
12.1.5. Communication specications
Digiware BUS
Function
Connection between DIRIS Digiware modules
Cable type
Specific SOCOMEC cable with RJ45 connections
USB
Protocol
Modbus RTU on USB
Function
Configuration of ISOM Digiware modules L and F
Location
On each ISOM Digiware module L and F
Connection
Type B micro USB connector