Recommended
cable type (min-
max AWG)
StorEdge Con-
nection Unit
connection
Auto-transformer
connection
Connection method
Temperature Sensor
Temperature sensor
terminal
24 AWG (16-24 AWG),
300 Vrms insulated
External Devices 7-pin
terminal block: T1
Temperature sensor
terminal: T1
1
StorEdge Connection Unit: Press
the protrusion at the top of the
terminal block to open the
connection hole, insert the wire
and release to spring back and
clamp the wire.
Auto-transformer:
o
Insert a flat blade screwdriver
into the square opening at the
top of the terminal block and
press to open clamp
mechanism.
o
Insert the wire into the round
opening and release the
screwdriver to spring back and
clamp the wire.
External Devices 7-pin
terminal block: T2
Temperature sensor
terminal: T2
1
T1 and T2 are interchangable
SolarEdge StorEdge Installation Guide MAN-01-000262-1.2
42
Connecting to the Auto-transformer

Table of Contents

Other manuals for SolarEdge StorEdge SE7600A-USS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge StorEdge SE7600A-USS and is the answer not in the manual?

SolarEdge StorEdge SE7600A-USS Specifications

General IconGeneral
BrandSolarEdge
ModelStorEdge SE7600A-USS
CategoryInverter
LanguageEnglish

Related product manuals