Configuration Menu Options
Country and Grid
1.
SelecttheCountry optiontospecifythecountryinwhichtheinverterisinstalledandthegridto
whichitisconnected.Thisparametermayarrivepre-configured.Ifso,verifythatitissettothe
propercountry.
WARNING!
The inverter must be configured to the proper country in order to ensure that it complies with the
country grid code and functions properly with that country grids.
L'onduleur doit être configuré pour le pays approprié afin d'assurer un fonctionnement convenable
avec le seau de ce pays.
Alistofcountriesisdisplayed.Ifnocountryisconfigured,thevalueis<NONE>.
NOTE
If an inverter is not configured to any country, it will not produce energy, and the following
message will be displayed on the LCD:
No Country Selected
Aplussign(+)nearthecountryindicatesthatanothermenuwillbedisplayedafterselection.
l WhenselectingAuto,theinverterautomaticallydetectstheusedgrid.
l WhenselectinganoptionwithNo NeutralorNo N,connectiontoNeutrallineisnotrequired.
Foranyotheroption,youmustconnecttheNeutralline.
2. Confirmyourcountryselectionintheconfirmationscreen:ToggletoYES andpressEnter.
Language
1. SelecttheLanguage optiontosetthelanguageinwhichtheLCDshoulddisplay.
2. Confirmyourlanguageselectionintheconfirmationscreen:ToggletoYESandpressEnter.
Communication
1.
SelecttheCommunication optiontodefineandconfigure:
l ThecommunicationoptionusedbytheinvertertocommunicatewiththeSolarEdge
monitoringplatform
l ThecommunicationoptionusedtocommunicatebetweenmultipleSolarEdgedevicesor
otherexternalnon-SolarEdgedevices,suchaselectricitymetersorloggers.
2. SelectServer tosetwhichcommunicationmethodisusedtocommunicatebetweendevicesandthe
SolarEdgemonitoringplatform.RefertoSettingUpCommunicationtotheMonitoringPlatformon
page69forafulldescriptionofthesecommunicationoptions.
NOTE
The Server menu shows only the communication options installed in the inverter.
ThefollowingshowsahierarchicaltreeofthemenuoptionsintheCommunication menu.
Fordetailedinformationaboutalltheconfigurationoptions,refertotheCommunication
OptionsApplicationNote,availableontheSolarEdgewebsiteat
http://www.solaredge.us/files/pdfs/solaredge-communication_options_application_
note_v2_250_and_above.pdf.
SolarEdge StorEdge Installation Guide MAN-01-000262-1.2