Communication Ports Status
D e v P r o t # #
R S 4 8 5 - 1 < S E > < S > < - - >
Z i g B e e < S E > < M P S > < - - >
l ##:Thetotalnumberofslavesdetectedonthespecificport
l Dev:Thetypeofdevicethatwasconfiguredtoaspecificport(basedontheportsfunctionality),as
follows:
o
SE:SolarEdgedevice(default)
o
LGR:Non-SolarEdgelogger
o
MLT:Multipledevices,suchasmetersandbatteries
o
HA:Homeautomationdevices(forloadmanagement)
l PROT:Theprotocoltypetowhichtheportisset:
o
ForaSolarEdgedevice:
RS485 protocol ZigBee protocol
S: SolarEdge slave
M: SolarEdge master
P2P: ZigBee point-to-point
MPM: ZigBee multipoint master (for the SolarEdge ZigBee
home gateway or for load management by the inverter)
MPS: ZigBee multipoint slave (for a ZigBee router card)
o
Forelectricitymeters,refertotheapplicationnote-ConnectinganElectricityMeter
toSolarEdgeDevicesathttp://www.solaredge.com/files/pdfs/solaredge-meter-
installation-guide-na.pdf.
o
SS:SunSpec-foranon-SolarEdgelogger(monitoringandcontrol)
Smart Energy Management Status
ThisscreenisdisplayedonlywhenSmartEnergyManagementisenabled.Thescreenshowsenergydetails
ofthesite:
S i t e L i m i t : 7 . 0 k W
S i t e P r o d : 1 0 . 0 k W
S i t e E x p o r t : 4 . 0 k W
S e l f - c o n s u m e : 6 . 0 k W
l Site Limit:Thelimitthatwasdefinedforthesite
l Site Prod:Thepowerproducedbythesite
l Site Export:Thepowerthatisfedintothegrid
l Self-consume:ThePVpowerconsumedbythesite
Formoreinformation,refertotheExportLimitationApplicationNote,availableonthe
SolarEdgewebsiteathttp://www.solaredge.us/files/pdfs/products/feed-in_limitation_
application_note.pdf.
SolarEdge StorEdge Installation Guide MAN-01-000262-1.2
66
Communication Ports Status

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge storedge and is the answer not in the manual?

SolarEdge storedge Specifications

General IconGeneral
TypeHybrid Inverter
TopologyTransformerless
Battery CompatibilityLG Chem, Tesla Powerwall
Communication InterfacesRS485, Ethernet
Frequency50 Hz / 60 Hz
Operating Temperature-25°C to 60°C
CoolingConvection cooling

Related product manuals