Communication Ports Status
D e v P r o t # #
R S 4 8 5 - 1 < S E > < S > < - - >
Z i g B e e < S E > < M P S > < - - >
l ##:Thetotalnumberofslavesdetectedonthespecificport
l Dev:Thetypeofdevicethatwasconfiguredtoaspecificport(basedontheport’sfunctionality),as
follows:
o
SE:SolarEdgedevice(default)
o
LGR:Non-SolarEdgelogger
o
MLT:Multipledevices,suchasmetersandbatteries
o
HA:Homeautomationdevices(forloadmanagement)
l PROT:Theprotocoltypetowhichtheportisset:
o
ForaSolarEdgedevice:
RS485 protocol ZigBee protocol
S: SolarEdge slave
M: SolarEdge master
P2P: ZigBee point-to-point
MPM: ZigBee multipoint master (for the SolarEdge ZigBee
home gateway or for load management by the inverter)
MPS: ZigBee multipoint slave (for a ZigBee router card)
o
Forelectricitymeters,refertotheapplicationnote-ConnectinganElectricityMeter
toSolarEdgeDevicesathttp://www.solaredge.com/files/pdfs/solaredge-meter-
installation-guide-na.pdf.
o
SS:SunSpec-foranon-SolarEdgelogger(monitoringandcontrol)
Smart Energy Management Status
ThisscreenisdisplayedonlywhenSmartEnergyManagementisenabled.Thescreenshowsenergydetails
ofthesite:
S i t e L i m i t : 7 . 0 k W
S i t e P r o d : 1 0 . 0 k W
S i t e E x p o r t : 4 . 0 k W
S e l f - c o n s u m e : 6 . 0 k W
l Site Limit:Thelimitthatwasdefinedforthesite
l Site Prod:Thepowerproducedbythesite
l Site Export:Thepowerthatisfedintothegrid
l Self-consume:ThePVpowerconsumedbythesite
Formoreinformation,refertotheExportLimitationApplicationNote,availableonthe
SolarEdgewebsiteathttp://www.solaredge.us/files/pdfs/products/feed-in_limitation_
application_note.pdf.