2.
PresstheexternalLCDlightbuttontodisplaythebatterystatusscreen,andcheckthat:
l ThebatteryStateis:Discharging/Charging
l TheSOEpercentageisdecreasing/increasing
l ThePWRvalueisgreaterthan0
B S N : X X X X X X X X X I D : 2 4
S O E : 8 9 % W W W W W P W R : 3 W
T o t a l : < x > W h
S t a t e : D i s c h a r g i n g
3.
TurntheACbackONfromthemaindistributionpanel.Theinvertershouldreconnectloadsbackto
thegrid.
To check Maximize Self-consumption mode:
1. VerifytheinverterON/OFFswitchisON.
2. Turnonasmanyloadssothatconsumptionisgreaterthantheinverter'smaximumACpower.
3. PresstheinverterLCDlightbuttontodisplaytheMeterstatusscreenandcheckthatimportpoweris
greaterthanzero:
I m p o r t M e t e r
S t a t u s : < O K / E r r o r # >
P o w e r [ W ] : x x x x x . x
E n e r g y [ W h ] : X X X X X . X
4. PresstheinverterLCDlightbuttontodisplaytheSmartEnergyManagementandtheBatterystatus
screens,andcheckthat:
o
State=Discharging(assumingconsumption>PVproduction;invertermaximumACpower>PV
production.
o
PWR>0
B S N : X X X X X X X X X I D : 2 4
S O E : 8 9 % W W W W W P W R : 2 W
T o t a l : < X > W h
S t a t e : D i s c h a r g i n g
5.
WhilethePVmodulesareexposedtosunlight,verifythatthebatteryischargingproperly:
a. Minimizeconsumptionbyturningoffalltheloadcircuitbreakers,exceptfortheinverter.
b. IntheinverterLCDcheckthattheMeterstatusscreenisdisplayingimportpowerclosetozero.
c.
PresstheexternalLCDlightbuttontodisplaytheBatterystatusscreen,andcheckthat:
l State=Charging
l SOEpercentageisincreasing
l PWR>0
B S N : X X X X X X X X X I D : 2 4
S O E : 8 9 % W W W W W P W R : 2 W
T o t a l : < x > W h
S t a t e : C h a r g i n g
SolarEdge StorEdge Installation Guide MAN-01-000262-1.2
86
Verifying StorEdge Components Functionality

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge storedge and is the answer not in the manual?

SolarEdge storedge Specifications

General IconGeneral
TypeHybrid Inverter
TopologyTransformerless
Battery CompatibilityLG Chem, Tesla Powerwall
Communication InterfacesRS485, Ethernet
Frequency50 Hz / 60 Hz
Operating Temperature-25°C to 60°C
CoolingConvection cooling

Related product manuals