110
Operation on LCD
• Reset INV Energy
===Reset INV Energy===
> Yes <
>Reset
=======Reset=======
Reset Meter/CT
>Reset INV Energy
Reset Wifi
• Reset Wifi
======Reset Wifi======
> Yes <
>Reset
=======Reset=======
Reset Meter/CT
Reset INV Energy
>Reset Wifi
• Factory Reset
=====Factory Reset=====
> Yes <
>Reset
=======Reset=======
Reset INV Energy
Reset Wifi
>Factory Reset
Setting Battery Heating
This function is disabled by default and is only valid when the battery has the heating
function. You can enable Battery Heating function to make the battery heated. And set the
heating period.
a. Enable the Battery Heating function.
====Battery Heating====
> Enable <
>Func Select
b. Set the heating start time and end time for the battery. Two heating periods can
be set.
>Heating Period 1
Start Time
00:00
====Battery Heating====
====Battery Heating====
====Battery Heating====
====Battery Heating====
>Heating Period 1
End Time
00:00
>Heating Period 2
Start Time
00:00
>Heating Period 2
End Time
00:00
Setting Extend BAT FUNC
This function allows for the extension of battery modules, such as adding a new battery
module to an existing system. It is only applicable and functional in on-grid mode and
cannot be used in EPS mode. In on-grid mode, enabling this function will make the inverter
to charge or discharge the battery SOC to approximately 38%. This function will turn to
Disable automatically after 48 hours this function enabled..