CAPACITOR ELECTRICAL DISCHARGE PROCESSING
When checking the board, the electrical discharge is necessary for
the electric shock prevention.
Connect the resistor to both ends of respective capacitors.
• D-AMP board
CN1000 (pin 6 and 10, pin 6 and 3)
• Switching regulator (SWR1)
C202, C203, C403, C407, C531 and C532
– Switching Regulator (Conductor Side) –
– D-AMP Board (Conductor Side) –
800 :/2 W
(for C403)
800 :/2 W
(for C407)
800 :/2 W
(for C531)
800 :/2 W
(for C532)
800 :/2 W
(for C203)
800 :/2 W
(for C202)
800 :/2 W
(pin 3 and 6)
800 :/2 W
(pin 6 and 10)
110
CN1000
MODEL IDENTIFICATION
Distinguish by Part No. and Destination code on the rear side of
a main unit.
– Rear View –
– Back Panel –
Part No.
Destination code
Part No. Destination code Destination
4-488-633-0[]
E4/SA2 African and South African
4-488-633-1[]
E12 Indian
4-488-633-2[]
E51 Chilean and Peruvian
4-488-633-3[]
E93
United Arab Emirates,
Kuwait, Iraq, Kenya,
Tanzania and Nigeria
4-488-633-4[]
SP6 Singapore and Malaysia
4-488-633-5[]
TH1 Thai
4-488-633-6[]
MX4 Mexican
4-488-633-7[]
E2 120V AC area in E
Ver. 1.3