47
Soundcraft Si Compact User Guide 1211
CLEAR
The CLEAR facility allows channels, buses or logical groups of channels to be reset to their
factory defaults. The operation is instigated by holding the CLEAR key while pressing one of the
following keys:
HPF — Sets HPF OFF and sets Filter value to Factory Default
Gate — Sets GATE OFF and sets Gate values to Factory Default
Comp — Sets COMP OFF and sets Comp values to Factory Default
EQ — Sets EQ ON and sets EQ values to Factory Default
LR — Sets LR routing ON, PAN/BAL to centre, delay to 0mS and all GrAux sends to Factory
Default
MONO — Sets MONO routing ON, PAN/BAL to centre, delay to 0mS and all GrAux sends to
Factory Default
SELect — Sets all channel audio parameters on SELected channel to Factory Default
NOTE: Patching and naming is NOT included in resetting a channel.
GLOBAL GAIN — On current layer sets all input gains on to factory default for selected source
type, +5db for mic sources, 0db trim for line sources
GLOBAL FILT — On current layer sets all HPF OFF and sets all lter values to factory default
GLOBAL PAN — On current layer sets all PAN or BAL controls to centre
MUTE MASTER 1—4 — Clears ALL slaves assigned to MUTE GROUP 'n'
BUS 1—14 — Sets sends from all channels to bus 'n' to Factory Defaults
MTX 1—4 — Sets sends from all buses to MTX 'n' to Factory Defaults
FX 1—4 — Sets sends from all channel to FX 'n' to Factory Defaults
GEQ HI or LO — Sets all GEQ bands to 0db for SELected bus
NOTE: Not all functions are present in all modes e.g. Buses have no HPF function, in these
events the action has no function.