© 2016 SPI Lasers UK Ltd.
Commercial in Confidence
SM-S00500 Revision A 21 October 2016
redPOWER QUBE Cased Fiber Laser User Manual
o The input is operational in both Remote and Local Control as follows
o In Local – The Trigger mode is configured using the parameter set
configuration.
o In Remote – The Trigger is configured using the Trigger Source Select if this
function is configured on the Machine Interface, or the active Parameter Set
settings are used if Trigger Source Select is not configured.
o If this function is not configured on the Machine Interface, the external Trigger
mode is specified by the active Parameter Set.
o This function can be assigned to any of the seven inputs, although it is
recommended to use Input 6, as this input uses higher bandwidth electronics.
o Associated functions
Trigger Source Select - Input Function
Sync - Output Function
Sequence diagrams
Figure 64 Edge Trigger Operation(Pulsed Output Only)