© 2016 SPI Lasers UK Ltd.
Commercial in Confidence
SM-S00500 Revision A 21 October 2016
redPOWER QUBE Cased Fiber Laser User Manual
Figure 17 PL5 Programmable Outputs
7.6.5.4 Basic Operation
With the basic connections above, supplying 24V to the inputs will assert them.
In order for the QUBE Fiber Laser to be fully controlled through the Machine Interface it is
necessary to put it in Remote Control mode via FiberView. This is done by clicking on the
control button (silhouette of a Man) on the main FiberView toolbar, which turns into a Cog to
indicate that Remote Control is selected. The control status indicator on FiberView will turn
red, and the text alongside it will change to REMOTE.
The necessary connections (based on the default configuration) to start using the QUBE Fiber
Laser in Remote Control mode are:
Laser Start (IN0, Pin 3)
This takes the QUBE Fiber Laser from the OFF state to the STANDBY (ready) state.
If this input is clear when entering Remote Control and the QUBE Fiber Laser is in the
ON state, the QUBE Fiber Laser will go to the OFF state.