redPOWER QUBE Cased Fiber Laser User Manual
113
12 Alarm and Warning Messages
12.1 Alarm Code Definitions
Each alarm code contains information about the zone, and module associated with the failure.
It can be broken down as follows:
Alarm Code = ZMNN
Where
Z is the zone associated with the alarm as described in Table 3 above.
M is the module number to identify devices where there is more than one.
NN is the alarm code identifying the problem.
12.1.1 PRISM FL Module Zone Alarms
Code
Description
8m01
Module Communications Failure
8m02
Temperature 1 Fault
8m03
Temperature 2 Fault
8m04
Temperature 3 Fault
8m05
Temperature 4 Fault
8m06
Temperature 5 Fault
8m07
Temperature 6 Fault
8m08
Snap Switch Faulty
8m09
Memory corruption fault
8m10
Auxiliary Power Supply Low Fault
8m11
Driver Power Supply not Present
8m12
Fiber Failure
8m13
BDO Open
8m14
BDO Short
8m15
Humidity
8m16
Internal Communications Failure
8m17
Unexpected Emission