Table 10 PL5 Machine Interface Pin Out
PIN #
I/O
PIN NAME
DEFAULT FUNCTION
1
PEXT
PEXT
External 24 Vdc
2
PEXT
PEXT
External 24 Vdc
3
I
IN0
Laser Start
4
I
IN1
Laser ON / Process Cycle Start
5
I
IN3
Unused
6
I
IN5
Unused
7
O
OUT1
Laser ON / Process Cycle Active
8
O
OUT3
Alarm Status
9
O
OUT5
Unused
10
O
AOUT
Laser Power Analogue Feedback
11
AI
AIN+
Analogue Input Demand Positive
12
-
-
-
13
I
COMMON
Digital Input Common Return path
14
GNDEXT
GNDEXT
External 0 Vdc
15
GNDEXT
GNDEXT
External 0 Vdc
16
I
IN6
Trigger Input (Recommended)
17
I
IN2
Process Cycle Step
18
I
IN4
Alarm Reset
19
O
OUT0
Laser STANDBY
20
O
OUT2
Remote Status
21
O
OUT4
Warning
22
O
OUT6
Process Cycle Wait
23
GNDEXT
GNDEXT
External 0 Vdc
24
AI
AIN-
Analogue Input Negative
25
-
-
-
Note:
The two PEXT 24V DC input connections are linked together internally. There is no
preference for connecting the 24V DC supply, and it is not necessary to use both.
The three GND EXT 0V DC input connections are linked together internally. There is
no preference for connecting the 0V DC supply, and it is not necessary to use all three.