17.3 Utility Requirements
17.3.1 Mains Power Requirement
The QUBE Cased Fiber Laser is powered by mains electricity. The supply requirements for all
QUBE Cased Fiber Lasers are given in Table 22. The power consumptions for QUBE Cased
Fiber Lasers with different rated powers are given in Table 23. The ranges of maximum supply
currents given in Table 23 correspond to the range of rated voltage given in Table 22, with
higher voltages requiring lower currents.
Table 22 Electrical Requirements
Parameter
Units
Min
Max
Supply phases
-
1
1
Rated voltage
(rated output power 500W)
V AC
100
240
Rated voltage
(rated output power >500W
V AC
200
240
Rated voltage tolerance)
%
10
Frequency
Hz
47
63
Table 23 Power Consumption
Rated Power
Units
300
500
750
1000
1500
W
Typical power consumption
1.1
1.8
2.7
3.6
5.4
kW
Maximum power
consumption
1.2
2
3
4
6
kW
Maximum supply current
7 5.5
11 9
16 - 14
22 18
32 27
A
17.3.2 Cooling Water Requirements
The QUBE Fiber Laser requires water cooling. The base plate within the body of the PRISM
FL Module has a cooling circuit. The PIPA-Q optical connector has a separate water cooling
circuit.
Requirements for the cooling water are given in Table 24. Permitted temperature ranges and
required flow rates, together with other parameters, for the base plate and PIPA-Q optical
connector are given in Table 25 and Table 27.

Table of Contents