11.2 Default Input Functionality
11.2.1 Summary
The default configuration of the Machine Interface inputs and outputs is given in Table 16 and
Table 17
Table 16 Default Configuration of Machine Interface Inputs
Input
Number
Pin on
PL5
Function
ID
Function Description
Reference
IN0
3
1
Laser Start
11.2.2
IN1
4
2
Laser ON / Process Cycle Start
11.2.3
IN2
17
5
Process Cycle Step
11.2.4
IN4
18
6
Alarm Reset
11.2.5
IN6
16
3
Trigger
11.2.6
Table 17 Default Configuration of Machine Interface Outputs
Output
Number
Pin on
PL5
Function
ID
Function Description
Reference
OUT0
19
1
Laser STANDBY
11.3.1
OUT 1
7
2
Laser ON / Process Cycle
Active
11.3.2
OUT 2
20
3
Remote Control
11.3.3
OUT 3
8
7
Alarm
11.3.4
OUT 4
21
8
Warning
11.3.5
OUT 5
9
9
Energy Warning (Future
Functionality)
11.3.6
OUT 6
22
5
Process Cycle Wait
11.3.7
11.2.2 Laser Start (Input Function ID 1):
Default connection
o PL5 pin number 3
o Input number 0
Basic Function Description
o Only operational in Remote Control.
o Takes the state from OFF to STANDBY under Remote Control

Table of Contents