11.2.3 Laser ON / Process Cycle Start (Input Function ID 2):
Default connection
o PL5 pin number 4
o Input number 1
Basic Function Description
o Multiplexed input depending on processing mode.
o Takes the state from the STANDBY state to the ON state and the ON state to
the STANDBY state under Remote Control in parameter set mode.
o Starts / stops a process cycle under Remote Control in process cycle mode.
o Input is edge sensitive in Remote Control.
o Input is level sensitive when entering Remote Control.
o Only operational in Remote Control.
Detailed Function Description
a) Parameter Set Operation
When the QUBE Fiber Laser is in Remote Control this input function provides the
following action:
o From the STANDBY state, setting the input changes the state to the ON state
or the RAMPING UP state if a ramp up time is configured in the active
parameter set.
o From the ON state, clearing the input changes the state to the STANDBY state
or starts the RAMPING DOWN state if a ramp down time is configured in the
active parameter set.
When in the STANDBY state and switching into Remote Control the Laser ON input is
acted upon depending on the initial state.
o When the state is the STANDBY state, and the Laser ON input is SET, the
state will not switch to the ON state when entering Remote Control. In this case
the Laser ON input is edge Triggered.
o When the state is the ON state, and the Laser ON input is CLEAR, the state
will change to the RAMPING DOWN (if any ramp is set) or STANDBY state
when selecting Remote Control. In this case the Laser ON input is level
sensitive.
o When the state is the ON state, and the Laser ON input is SET (and the Laser
Start input is either not configured or configured and SET), the state will remain
the ON state. In this case the Laser ON input is level sensitive.
o When the state is the OFF state, or transitioning to the STANDBY state, and
the Laser ON input is SET, the state will not transition to the ON state when it
enters STANDBY.