redPOWER QUBE Cased Fiber Laser User Manual
7.6.5.6 Status Outputs
Status outputs are provided at the Machine Interface. Connection details are shown in Figure
15. Table 12 shows the full list of functions that can be configured to apply to any of OUT0 -
OUT6 as shown in Table 10.
Table 12 Laser Status Outputs
Output Function Description
False: QUBE Fiber Laser OFF or ON
True: QUBE Fiber Laser in STANDBY
Laser ON / Process Cycle Active
False: QUBE Fiber Laser OFF/STANDBY or
Process Cycle Stopped
True: QUBE Fiber Laser ON or Process Cycle
Running
False: LOCAL control Mode
True: Remote Control Mode
Synchronised True with duration of laser pulsing.
False: Process cycle running or in Autostep
mode.
True: Waiting for Process Cycle Step input
False: Normal Mode
True: Process Cycles Mode
False: Alarm not present
True: Alarm present
False: Warning not present
True: Warning present
False: Data not accepted or strobe off
True: Data accepted
Parameter Set / Process Cycle
Selected (Bit 0)
Provides monitor output to confirm parameter set
or process cycle selected
Parameter Set / Process Cycle
Selected (Bit 1)
Parameter Set / Process Cycle
Selected (Bit 2)